Autoclaves PHCBi

PHCBi_Panasonic_new_logo [Converted]

MLS – 2040U

Digital controls and display eliminate setting errors The digital control panel allows temperature and time settings to be entered accurately in 1ºC and 1-minute intervals. The display panel is easy to read helping to prevent errors when setting parameters. Pressing the (TEMP) and (TIMER) keys simultaneously displays the remaining sterilisation time.
Safety assured with fail-safe functions 1. Dry scorch protection function Should the water level drop too low, an overheating protection circuit is triggered, a buzzer sounds and an error message appears on the display. Buzzer alert: pairs of short beeps repeated in succession. 2. Door switch A safety mechanism prevents the autoclave from operating if the door is not completely closed. A door closed lamp lets you check whether the door is closed.
3. Pressure safety valve A reliable pressure safety valve is used to prevent the pressure inside the chamber from rising above acceptable levels. 4. Thermistor error detector function If the thermistor temperature sensor goes open circuit (connection broken), the heater turns off to prevent overheating. Buzzer alert: pairs of short beeps repeated in succession. 5. Overheating protection function The digital display starts to flash if the temperature in the chamber rises more than 2ºC above the temperature setting. If it rises 3ºC or more above the setting, the relay shuts off and cuts off power to the heater. 6. Door protection function If the magnet-holder is not connected to the switch button, the high pressure lamp will flash when the temperature inside the chamber is over 99ºC.

MLS – 3020U

Digital controls and display eliminate setting errors The digital control panel allows temperature and time settings to be entered accurately in 1ºC and 1-minute intervals. The display panel is easy to read helping to prevent errors when setting parameters. Pressing the (TEMP) and (TIMER) keys simultaneously displays the remaining sterilisation time.
Safety assured with fail-safe functions 1. Dry scorch protection function Should the water level drop too low, an overheating protection circuit is triggered, a buzzer sounds and an error message appears on the display. Buzzer alert: pairs of short beeps repeated in succession. 2. Door switch A safety mechanism prevents the autoclave from operating if the door is not completely closed. A door closed lamp lets you check whether the door is closed.
3. Pressure safety valve A reliable pressure safety valve is used to prevent the pressure inside the chamber from rising above acceptable levels. 4. Thermistor error detector function If the thermistor temperature sensor goes open circuit (connection broken), the heater turns off to prevent overheating. Buzzer alert: pairs of short beeps repeated in succession. 5. Overheating protection function The digital display starts to flash if the temperature in the chamber rises more than 2ºC above the temperature setting. If it rises 3ºC or more above the setting, the relay shuts off and cuts off power to the heater. 6. Door protection function If the magnet-holder is not connected to the switch button, the high pressure lamp will flash when the temperature inside the chamber is over 99ºC.

„MLS – 3751“

Surprisingly Large Chamber Despite the compact outer dimensions of these autoclaves, they store 8 (MLS-3751L) or 12 (MLS-3781L) 1,000ml flasks. The MLS-3751L has two baskets, and the larger MLS-3781L has three.Compact Design, Swing-up Lid for Easy Access Both Panasonic models can be easily installed in minimal space. A swing-up lid provides effortless access for loading and unloading test tubes, flasks and lab instruments.Thermal printer (optional) The work conditions shown on the control panel (temperature/pressure inside chamber, sterilizing course, time) can be printed out by a line thermal dot printer for record-keeping, management, and storage.Microprocessor temperature control Sterilizing temperature is controlled to within +2°C/-0°C of the set temperature in the range of 115°C to 135°C. Air vent control Can be set to allow automatic release after sterilizing is completed.

„MLS – 3781L“

Newly designed handle lets users open and close the lid easily with one hand. The conventional slide handle has been completely redesigned to develop a hand-pull system that enables easy opening/closing by gripping with one hand. In addition, the cover is equipped with a scalding prevention guard to prevent scalding due to steam.Equipped with 4 selectable courses and 3 customizable programs Any of 4 courses can be selected according to the purpose of use, and 3 types of setting values can be stored for each course according to the usage conditions. The setting values (sterilizing temperature, sterilizing time, melting temperature, melting time, keep warm, exhaust temperature, exhaust rate) for each program can be easily changed by the user for easy use.Functions for user safety and cooling fan/exhaust level adjustment to reduce cooling time. Conforming to the requirements of IEC standards, when using sterilizing liquid the temperature when opening the cover is set to 65°C or less. In addition, by adding exhaust holes at several positions on the side of the product and positioning the standard-equipment cooling fan under the chamber, cooing efficiency and sterilizing efficiency are increased, so that operating time can be reduced. Furthermore, a constant open/close interval (with 5-step adjustment) for the exhaust process valve enables selection of the exhaust rate for steam inside the chamber to enable cooling in a shorter time while reducing exhaust time and preventing boiling over of sterilizing liquid.